Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Arthroplast Today ; 27: 101371, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38585285

RESUMEN

Background: Additive manufacturing has recently gained popularity and is widely adopted in the orthopaedic industry. However, there is a paucity of literature on the radiographic and clinical outcomes of these relatively novel components. The aim of this study was to assess the 2-year clinical and radiographic outcomes of a specific additive-manufactured acetabular component in primary total hip arthroplasty. Methods: We performed a retrospective review of 60 patients who underwent primary total hip arthroplasty with the use of the Stryker's TRIDENT II acetabular component. Evaluation of radiographs was performed at 6 weeks, 1 year, and 2 years postoperatively. Radiographs were evaluated for radiolucencies in Charnley and DeLee zones, signs of biologic fixation, and acetabular inclination and anteversion measurements. Patient-reported outcomes and complications were also obtained. Results: There were no cases of component loosening or changes in component position during follow-up, with an average follow-up time of 1.7 years. A radiolucent line was identified in one patient in zone 1 at 6 weeks; this was absent at 1 year. Radiographic signs of cup biologic fixation were present in 85% of cases by final follow-up. The average inclination was 45.1 (SD = 4.0), and the average anteversion was 26.9 (SD = 5.2). Patient-Reported Outcomes Measurement Information System scores significantly increased at the final follow-up, and there were no complications in this cohort. Conclusions: This study demonstrated excellent radiographic and clinical outcomes with this novel additive-manufactured acetabular component at early follow-up. Although longer-term follow-up is warranted, this additively manufactured highly porous titanium acetabular component demonstrated excellent biologic fixation and reliable fixation at mid-term follow-up.

2.
J Arthroplasty ; 39(2): 527-532, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37572723

RESUMEN

BACKGROUND: Arthroplasty is one of the least gender-diverse orthopaedic subspecialties. While previous studies have looked at factors influencing fellowship choices for women, few studies have attempted to understand the decision for or against arthroplasty specifically. Working to better understand fellowship choice is a critical step in the process of increasing women recruitment. METHODS: An anonymous survey was distributed using REDCap to women orthopaedic surgeons and trainees through listservs, social media groups, and residency programs. Surgeons who had decided on a specific subspecialty or already completed fellowship were included. Responses were obtained from 164 surgeons (72 arthroplasty surgeons, 92 other subspecialties). Chi-squared and Fisher's Exact tests were then performed. RESULTS: The most important factor for those who chose arthroplasty was enjoyment of the surgeries. The biggest concerns from those in the arthroplasty group about the field were work-life balance, ability to become pregnant and/or have a healthy pregnancy, and sex bias from referring physicians. Of those who ultimately chose another subspecialty, 30.4% considered arthroplasty "a little" and 8.7% considered it "strongly." The most important dissuaders for the group that considered arthroplasty were concerns about "boy's club" culture, concerns about the physicality of the surgeries, and a lack of mentors. CONCLUSION: While the decision to choose a career path is multifactorial, our hope is that through the identification of modifiable factors we can increase women representation in arthroplasty. Increasing mentorship, implementing practical solutions to improve work-life balance, supporting healthy pregnancies, and mitigating the physical demands of surgery could help address current disparities.


Asunto(s)
Internado y Residencia , Cirujanos Ortopédicos , Ortopedia , Cirujanos , Masculino , Embarazo , Humanos , Femenino , Becas , Motivación , Artroplastia , Ortopedia/educación
3.
J Arthroplasty ; 37(8): 1464-1469, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35247485

RESUMEN

BACKGROUND: Intraoperative fluoroscopy is an essential tool to assist orthopedic surgeons in accurately and safely implanting hardware. In arthroplasty cases, its use is on the rise with the increasing popularity of the direct anterior (DA) approach for THA. However, exposure of ionizing radiation poses a potential health risk to surgeons. While the benefits of intraoperative fluoroscopy in DA THA is becoming clearer, and are well-described in the literature, the potential health dangers associated with career-long cumulative radiation exposure are rarely discussed. METHODS: In this article, we review the available literature to discuss radiation safety in orthopedics with a focus on total joint arthroplasty. We present the basic science of radiation, discuss the amount of radiation exposure in orthopedic surgery, and review the potential health risks associated with long-term exposure. CONCLUSION: Overall, the radiation dose exposure to arthroplasty surgeons is low and within recommendations for occupation exposure limits. However, due to the stochastic health impacts of ionizing radiation, there is no threshold dose below which radiation exposure is truly safe. Therefore, it is imperative that surgeons practice proper fluoroscopy safety habits, such as wearing proper protective equipment, minimizing fluoroscopy time and magnification, and maximizing distance from the radiation source to minimize the life-long cumulative radiation exposure and associated health risks.


Asunto(s)
Artroplastia de Reemplazo , Exposición Profesional , Exposición a la Radiación , Cirujanos , Artroplastia de Reemplazo/efectos adversos , Fluoroscopía/efectos adversos , Humanos , Exposición Profesional/prevención & control , Dosis de Radiación , Exposición a la Radiación/efectos adversos
4.
J Arthroplasty ; 36(6): 2178-2183, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33632579

RESUMEN

BACKGROUND: Two-stage revision remains the standard of care for prosthetic joint infection after total hip arthroplasty. However, there are substantial complications associated with articulating antibiotic hip spacers. Handmade and molded spacers have been shown to have higher rates of spacer fracture than antibiotic-coated prostheses (ACPs). The aim of this study is to review outcomes with an implant that is often categorized as an ACP spacer, the Zimmer-Biomet StageOne Select Femoral Spacer (ZBSO). METHODS: A retrospective review was performed of 63 patients who underwent placement of a ZBSO. Patients were compared based on whether or not an extended trochanteric osteotomy (ETO) was performed using Fisher's exact and t-tests. RESULTS: Five patients were excluded due to lack of follow-up or death shortly after stage 1 surgery, leaving 58 patients. Spacer fracture was noted in 5 of 58 patients (8.6%). Sixteen patients underwent ETO and 25.0% suffered a spacer fracture compared to 2.3% without ETO (odds ratio 13.7, P = .0248). There was no association between patient demographics or ETO length and spacer fracture. Two patients had periprosthetic fractures (3.4%) and 4 had dislocations (6.9%). Forty-nine patients (84.4%) went on to second-stage revision; of those 26.5% failed to clear the infection and required an average of 2.2 additional surgeries. CONCLUSION: The ZBSO spacer has overall complication rates similar to previously reported spacer series. Although the ZBSO looks like an ACP spacer, in the setting of ETO, it behaves like a molded or handmade spacer with a high rate of spacer fracture (25%) due to the small diameter of the core. This implant should be used with caution in combination with an ETO.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Infecciones Relacionadas con Prótesis , Antibacterianos , Artroplastia de Reemplazo de Cadera/efectos adversos , Humanos , Osteotomía , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Prótesis/cirugía , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...